Conference Interpretation Services

Conference Interpretation Services
Details:
The charging box can charge 24 receiving units at the same time, and has functions such as storage, protection, dust proof, and portability. It is a product specially equipped for simultaneous interpretation systems.
Send Inquiry
Download
Description
Specification
FAQ

Features

 

 

● The power input adopts AC110V-220V AC power supply, which is compatible with specifications in different regions.

● Can charge 24 receiving units at the same time, and also has storage function, practical and convenient.

● With protective cotton and protective box, it can prevent dust, moisture and collision for the receiving unit.

● The charging box is also equipped with a telescopic pull rod and pulley, which is portable and labor-saving, and easy to move.

● Equipped with charging protection and charging indication functions to ensure charging safety and intuitive and easy to use.

 

Connection

 

 

product-662-572

 

Hot Tags: conference interpretation services, China conference interpretation services manufacturers, factory, 5 Ceiling Speaker, 4 Inch Ceiling Speaker, Two Way Ceiling Speaker, Large Conference Room Microphone, IP Paging Microphone, Small Wall Speakers

Specification

 

 

Power supply

AC110V-220V

Power

66W

Number of charging digits

24

Maximum charging current per unit

220mA

Charging time

about 2-2.5 hours

Status indicator

Red light on - charging; green - charging completed

Working temperature

0℃-40℃

Dimensions

630×370×290mm

Weight

10.5kg (without battery)

Q: How to ensure the stability of the internal circuit of the Conference Interpretation Services and avoid malfunctions when it is working at high load for a long time?

A: Cooling fan: Install a high-performance cooling fan in the charging box to remove the heat generated by the circuit through air convection. Reasonably design the air duct so that air can flow effectively in the box to ensure even heat dissipation. For example, install the fan in a suitable position so that cold air enters from the air inlet and is discharged from the exhaust port after passing through the heating element.

Overcurrent protection: Install an overcurrent protection device, which automatically cuts off the circuit when the current in the circuit exceeds the set safety value to prevent components from burning out due to excessive current. This protection device usually uses a fuse or circuit breaker, which can quickly respond to overcurrent conditions and ensure circuit safety.

Send Inquiry