Product Overview
At YZ AUDIO, we offer the Outdoor Network Intercom Panel as a fixed communication point for entrances, outdoor help locations and supervised access areas. It gives visitors and staff a direct way to contact a control room through a network-connected intercom panel, bringing conversation to locations where a broadcast loudspeaker alone cannot collect a spoken reply.
Our published design combines a call button, microphone and local speaker with Ethernet connectivity. Full-duplex operation allows both parties to speak during the same conversation, helping operators clarify a visitor's request without a push-to-talk exchange. For system integrators, distributors and project contractors, the buying decision starts with the receiving station, network topology, installation environment and required response workflow.
Compared with a dedicated analog intercom circuit, an IP endpoint can use a managed data network and support remote maintenance where the software configuration permits. We recommend checking the complete call path before selecting quantities: panel, network, server or receiving station, and backup power. Outdoor placement also requires confirmation of enclosure protection and cable-entry sealing for the actual site.

Request a Quote for Outdoor Network Intercom Panel today
Key Features
- Two-way communication at the help point. A single call button and full-duplex voice function support direct contact with an operator. The intercom panel is intended for a local conversation, so acoustic placement should prioritize the person standing at the panel rather than broad-area music coverage.
- Ethernet connection for distributed locations. The published RJ45 interface supports a 100 Mbps network connection. This makes the panel suitable for consideration in structured network designs, with routing and access permissions reviewed for each deployment.
- Remote maintenance functions. The product description lists individual and batch remote upgrades, plus hardware resource monitoring. These functions can reduce the need to visit every installed endpoint; confirm the management software version, licenses and supported operations in the quotation.
- Audio processing for conversation. The feature description identifies acoustic echo cancellation, noise reduction and automatic gain control. Their practical benefit depends on mounting position, local noise and firmware settings, so include a two-way voice demonstration in sample evaluation.
- An analog output for system integration. The specification lists a 1 V output and 600-ohm output impedance. This provides an integration point for a compatible audio input; it is not a direct connection to a 100 V loudspeaker circuit.
- Defined power and environmental planning. The published supply is DC24V, and the stated operating range is −20°C to +60°C. Confirm enclosure protection separately before approving an exposed installation; an outdoor product name does not establish a tested ingress rating.
Contact us to discuss your Outdoor Network Intercom Panel project
Customization & OEM/ODM Services
Discuss an OEM/ODM intercom panel around your installation drawings and operating workflow. Candidate changes include logo artwork, faceplate color, enclosure finish, packaging, connector arrangement and installation method. Power-stage changes, additional input or output channels, protocol support and management-software functions require engineering review; they are not automatically available options.
Start with the destination market, order quantity, receiving platform, mounting location and required call behavior. A feasibility review should establish the hardware revision, firmware scope, tooling charges, compliance implications and acceptance criteria before a sample is approved. This avoids treating a visual customization as proof that new software functions have also been delivered.
MOQ: 100 units. Sample lead time: 7–15 working days after artwork approval. For evaluation units, contact our sales team to discuss arrangements. New enclosure tooling and software development require separate schedules and minimum quantities. Contact us with your drawings and protocol requirements to obtain a confirmed customization proposal.

Why Choose YZ AUDIO
Our company profile describes a manufacturing base of approximately 80,000 m², 200 staff, 30 R&D engineers and six SMT lines, alongside reflow and machining equipment. These are company-wide figures supporting an annual production capacity of 100,000 units per year. For a phased rollout, request a capacity statement and delivery allocation.
We approach the purchasing discussion around the complete communication task: who presses the button, who receives the call, how the network is maintained, and what happens when power is interrupted. For sample approval, agree a test record covering call establishment, two-way speech, output level, remote maintenance and recovery. This is a proposed acceptance process; completed test reports should be supplied for the actual hardware and firmware rather than inferred from general company claims.
Our company page lists CE, RoHS and ISO9001 among its credentials. Ask for the applicable declaration, supporting reports and current certificate scope. A company management-system certificate does not certify every intercom configuration, and custom hardware may require reassessment.
Responses are provided within 24 hours. Standard dispatch is 15 business days; customized production is 30 working days. Warranty: 1 year; expected service life: 5 years. Request the written support terms with your quotation.
For OEM and recurring orders, we recommend confirming the approved golden sample, packaging revision, inspection checklist and shipment schedule in the purchase documentation. Integrators should also request the operating manual, wiring diagram and any applicable compliance reports. Send us the installation country, intended use, quantity and requested delivery date to obtain a quotation and an evidence-backed statement of lead time, warranty and certification coverage.
Application Scenarios
- Campus entrances. Position an intercom panel at a supervised gate so visitors can contact reception. Coordinate call routing with the campus IP broadcast team and verify outdoor installation protection.
- Industrial parks. Use a fixed help point near controlled vehicle or pedestrian access. Test conversation during representative machinery noise and confirm the receiving operator's availability.
- Commercial complexes. Provide a contact point at service entrances or parking access areas. Define responsibility for answering calls across security and property-management teams.
- Transport hubs. Consider panels at staffed assistance locations after checking the operator's accessibility and emergency-communication requirements. This product is not presented as a certified life-safety system.
- Smart communities. Connect entrance assistance points to the selected management workflow. Door-release interfaces, resident calling and third-party integration require explicit confirmation.

FAQ
Q: How does customization work?
A: Send artwork, drawings, platform details and acceptance requirements. We can discuss feasibility, sample approval and production release, with any engineering work separately quoted; contact us to review your intercom panel project.
Warranty: 1 year, including covered faults, exclusions, return freight and remedies. Request the applicable written policy before ordering.
Request a paid evaluation sample to test mounting, voice communication and software compatibility. Sample lead time is 7–15 working days after artwork approval; contact us for sample cost, freight and timing.
Q: Does the panel support PoE or every SIP platform?
A: The published supply is DC24V; PoE is unconfirmed. SIP is mentioned in the feature description, but interoperability requires verification against your platform and firmware; send us the system details for review.
Q: Is it suitable for fully exposed outdoor installation?
A: Temperature limits do not establish an IP or IK rating. Confirm enclosure testing, cable seals and installation protection for your site; contact us with location photographs and environmental requirements.
Sources
[1] Product page and specification table: https://www.yzaudio.net/pa-system/ip-pa-system/outdoor-network-intercom-panel.html
[2] YZ AUDIO company profile: https://www.yzaudio.net/about-us
[3] IETF RFC 3550, RTP transport and its limitations: https://www.rfc-editor.org/rfc/rfc3550
[4] ITU-T G.114, one-way transmission delay guidance: https://www.itu.int/rec/T-REC-G.114
Technical Specifications
|
Parameter |
Published value |
|
Network |
RJ45; 100 Mbps |
|
Protocols |
RTP, UDP, TCP/IP, FTP |
|
Audio files and resolution |
MP3/WAV; 16-bit |
|
Sampling rate |
8–48 kHz |
|
Analog output |
1 V; 600 Ω; source labels level "0 dB" |
|
Frequency response |
Signal output: 30 Hz–20 kHz; power output: 50 Hz–20 kHz |
|
THD and signal-to-noise ratio |
THD ≤0.05%; SNR ≥80 dB |
|
Supply and consumption |
DC24V; AC220V adapter listed; 3 W consumption* |
|
Environment |
−20°C to +60°C; 20–80% RH, non-condensing |
|
Dimensions and weight |
193 × 107 × 44 mm; 0.75 kg |
|
Channels and software |
Feature text lists 1 analog output; software version and call capacity unconfirmed |
Network and protocols. Ethernet speed describes the link, not the number of concurrent calls. RTP carries real-time media but does not itself guarantee delivery or quality of service. SIP appears in the feature description but is absent from the specification table; verify the supplied firmware and receiving platform.
Files and sampling. MP3/WAV identifies file support, not the negotiated intercom codec. The 16-bit and 8–48 kHz entries describe audio representation; confirm which rates apply to live calls. Higher sampling rates can preserve more audio bandwidth but do not independently establish intelligibility.
Output and audio performance. Match the 1 V signal and 600-ohm source impedance to the receiving input's sensitivity and impedance. The stated "0 dB" reference is undefined. Electrical frequency response does not represent the built-in speaker's acoustic response. THD and SNR need test bandwidth, load and level conditions for meaningful comparison.
Power and installation. DC24V requires the specified supply arrangement; RJ45 does not prove PoE capability. *The 3 W consumption entry conflicts with a separate feature claim of up to 30 W amplifier output, so do not size the power supply from that figure. Dimensions and weight guide positioning, but mounting cutouts require a drawing. Temperature and non-condensing humidity limits do not establish rain, dust or corrosion resistance.
Capacity and continuity. Physical output channels are different from simultaneous calls or software zones. Confirm software licensing, call priority, backup-server behavior and power recovery separately. For evaluation, use ≤150 ms one-way end-to-end voice delay as a proposed project target, not a measured product rating; ITU-T G.114 explains delay sensitivity. Test with the intended network and codec.
Need custom specs? Get a quote now